Rapid sizing

Walter WH30 power fuse introduction

Date: 2024-07-23 Viewed:325

Walter WH30 power fuse is one of the power protection components produced by Walter Electronics Co., Ltd., mainly used for overload and short circuit protection in circuits. According to the search results, Walter WH30 power fuses come in various specifications to meet the protection needs of different currents and voltages. For example, some models are suitable for 500V DC voltage with a breaking capacity of up to 300A, while others are suitable for 400V DC voltage with a breaking capacity of up to 2000A. These fuses are usually made of ceramic materials, which have good insulation performance and high temperature resistance, and can provide stable and reliable protection in the power system

The specifications of Walter WH30 power fuses are quite diverse, and suitable models can be selected according to different application scenarios. Here are some typical specification parameters:

ModelCurrentVoltageBreaking abilityRemarks
WN30-0.2200mA500VDC/400VDC300A/2000A
WN30-0.4400mA500VDC/400VDC300A/2000A
WN30-0.6600mA500VDC/400VDC300A/2000A
WN30-11A500VDC/400VDC300A/2000A
WN30-1.251.25A500VDC/400VDC300A/2000A
WN30-1.61.6A500VDC/400VDC300A/2000A
WN30-2.52.5A500VDC/400VDC300A/2000A
WN30-1010A500VDC/400VDC300A/2000A
WN30-1212A500VDC/400VDC300A/2000A
WN30-1515A500VDC/400VDC300A/2000A
WN30-2020A500VDC/400VDC300A/2000A

When installing Walter WH30 power fuses, the following points should be noted:

  1. Choose the appropriate location: The fuse should be installed in an easily accessible and monitored location, and consideration should be given to possible replacement needs in the future.

  2. Ensure good contact: The connection between the fuse and the circuit must be firm to avoid overheating or breaking due to poor contact.

  3. Compliance with safety regulations: During installation, appropriate safety measures must be taken, such as operating in the event of a power outage, to prevent electric shock accidents.

  4. Consider environmental factors: The installation location should avoid the accumulation of dust and other pollutants, which may affect the performance of the fuse.

  5. Regular Inspection: Fuses should be checked regularly to ensure that they are in good working condition and damaged fuses should be replaced in a timely manner.

  6. Correct selection of specifications: When choosing a fuse, the appropriate specifications should be selected based on the actual circuit parameters and working conditions to ensure effective protection of the circuit.

In summary, Walter WH30 power fuse is a stable and versatile circuit protection product suitable for various power system environments. During installation and use, relevant operating procedures and safety standards should be strictly followed to ensure the safety and reliability of the circuit